DualProof T
High quality pre-applied PVC waterproofi ng membrane
DualProof T is a fully and permanently mechanical bonded pre-applied PVC waterproofing membrane. It consists of a special nonwoven PP-fleece co-extruded with a highly flexible PVC membrane designed for use with structural reinforced concrete.
DualProof T is cold-applied and pre-applied, as it is installed without heat or open-flames, and before the steel reinforcement is fixed and the concrete is poured.
Once poured, the fresh concrete is embedded completely into the special developed and designed fleece and creates a unique and permanent mechanical bond which prevents any lateral water migration, even in the event of any local damage to the membrane.

- No water migration between membrane and concrete structure.
- Tough and resistant, quick and easy to install, high compound shear strength.
- Can be installed in every season, independently of temperature and weather condition.
- Long term watertight durability.
- Assured watertight integrity – over bridges cracks.
- Protects structures against ground contaminants and salt water.
- Excellent solution for in-situ concrete.
Waterproofing of:
- Water under hydrostatic pressure.
- Lateral water migration for deep, one or multilevel below grade structures.
- Additional sealing membrane to all watertight concrete structures.
Concrete protection against:
- Various gases of the ground (Radon Test).
- Different types of chemicals in solution (sulphate, chloride, carbonate, hydrogen carbonate, etc.).
- Contaminated ground water.
Damp-proofing against:
- Rising humidity through capillary action.
- Percolating water, for slab-on-ground foundations, column footings, strip foundations, and walls.
DualProof T rolls must be stored in their original packaging, away from direct sunlight in cool, dry and frost-free conditions. Shelf life is 5 years.
DualProof T complies with EN 13967 as Flexible waterproofi ng membrane for all kinds of below ground structures against pressurised water. DualProof T is also used to provide all grades of basement protection in accordance with BS 8102:2009.