Cookie Consent by FreePrivacyPolicy.com
Water Repellent Coatings

Tools and Equipment

Surface Preparation

 

  • Surface must be clean, sound and free from oil, grease, curing compound, or any contamination. Any contaminants should be removed by light grit blastig.
  • Water jet is then used as the end step of substrate cleaning.

Application

  • It is recommended to apply two consecutive coats of water repellent coating at the stated rate of application with a maximum recoat time of 10 minutes, or one flood coat.
  • Impregnation can be carried out using an airless spray machine, brush, or roller.

Recommendations

  • Water repellents should not be applied on glass, wood, plastic, aluminum and metals.
  • Rinse immediately with water in case of accidental exposure.
  • Water repellents should not be applied when rain is forecasted within 24 hours.
  • Wait at least 24 hours after rain or water cleaning.
  • Be sure that impregnated surfaces by water repellents are not exposed to water and rain for at least 8 hours after application.
  • Allow the treated surface to dry for at least 24 hours to develop maximum water repellency.
     

DCP range of water repellents

Repelicone K : Water repellent impregnation based on water borne silicone.

Repelicone L : General purpose water repellent impregnation based on solvent borne Silane/Siloxane.

Repelicone W : Water repellent impregnation based on water borne Silane/Siloxane.

Rep-Stone : Water repellent impregnation based on water borne silicone